1, compact structure
Small size, cost-effective. Multiple units can be installed in parallel, saving space.
2, high starting torque performance
Full load speed torque test: full load rated output torque of electrical material output 102.4Nm; SVC control speed passive measurement of 0.2%; SVC control steady speed accuracy measured 04%.
3, instantaneous stop function
This function means that the inverter will not stop in the event of a momentary power failure. In the event of a momentary power outage or a sudden drop in voltage, the inverter reduces the output speed, and the energy is returned by the load to compensate for the voltage drop to maintain the inverter in a short period of time.
4, perfect braking function
The overexcitation function can effectively suppress the increase of the bus voltage during deceleration and avoid frequent overvoltage faults.
5 Built-in PID function
Built-in PID regulator, with the choice of frequency given channel, the user can easily achieve automatic adjustment of process control, to achieve such control applications as constant temperature, constant pressure, tension.
6, swing frequency function
In textile and chemical fiber processing equipment, the use of pendulum frequency function can improve the even and dense winding of the spindle.
7、Multi-motor switching function
Four sets of motor parameters can be stored, and one inverter can control the operation of four motors in a time-sharing manner.
8, timing control function
Timed running function, running time can be set by parameters and analog quantity.
9, support a variety of field bus
Standard RS485 communication interface supports Modbus RTU communication, CANopen and CANink can be extended to realize fast bus connection with Inovance products.
10, powerful background software
Supports inverter parameter operation and virtual display function. The visual monitoring of the internal state of the frequency converter can be achieved through the virtual display.
11, with the input phase protection, motor short-to-ground and motor phase short circuit protection
Comprehensive protection and more reliable operation.
12, a full range of standard configuration built-in braking unit
Standard brake unit, the user directly connected to the braking resistor, without external braking, saving costs.
13, a full range of product maintenance and maintenance
Can monitor the temperature of the module and the radiator, the upper computer can read and display;
Accumulated power consumption, running time and power-on time, upper computer communication reading;
The fan can be selected for power on or startup to effectively extend the life of the fan.