1.power wires | the three color connect to U,V,W / Yellow and green one connect to ground | ||||||||
Temperature control cable | 110℃ two phase thermistor connect to temperature controller | ||||||||
2.water outlet | (2 and 6 is connected with 8/6 flexible pipe) | ||||||||
3.Dedusting tool changer pressure | 0.2Mpa | ( 4/6 flexible pipe) | |||||||
4.air-seal pressure | 0.1Mpa | ( 4/6 flexible pipe) | |||||||
5.unload-tool inlet pressure | 0.70Mpa | ( 4/6 flexible pipe) | |||||||
6.water inlet | water pump lead 12m(make sure the connection is right) | ||||||||
7.Number of proximity switch | two proximity switches: NPN type | ||||||||
proximity switch conecting method: | brown wire connect + 24VDC | blue wire connect +0VDC | |||||||
signal -loading port + 24VDC | The other side conect to black wire | ||||||||
8.The compressor gas must be clean and dry, the filter fineness must be more than 0.5um. We recommend you choose two-stage filtration, the filter acuracy is 0.5um, and more than 0.5um |